Yacht Air Conditioning/Self-Contained Unit

Features

This self-contained unit, has standard stainless steel, using rivet stainless steel metal structure, and nickel-copper coaxis tube as heat exchanger for sea water side. The fan duct can be roted as required when you install it.The fan blower has advantage such as high static pressure, big air flow and low noise. This self-contained unit has the maximum compact design and better performance. As customer required, we can also provide D-smart control PCB with soft-start function to minimize the starting current.

Model

MS6-E2C

MS9-E2C

MS12-E2C

MS16-E2C

Power supply

Ph-V-Hz

1Ph/220V/50Hz

Cooling

Capacity

BTU

6,000

9,000

12,000

16,000

Input power

W

430

720

980

1,210

Rated current

A

2.0

3.3

4.5

5.5

EER

4.1

3.7

3.6

3.9

Heating

Capacity

BTU

6,500

10,000

13,300

17,700

Input power

W

450

770

1,000

1,270

Rated current

A

2.1

3.5

4.6

5.8

COP

4.2

3.8

3.7

4.0

Max.current

A

3.0

5.3

6.8

8.2

Sea water flow

M3/h

0.42

0.64

0.85

1.15

Indoor air flow

M3/h

250

630

630

810

Dehumidification capacity

L/h

0.7

1.1

1.8

2.1

Noise level

dB(A)

≤45

≤50

≤50

≤54

Dimension(L*W*H)

mm

461X265X283

602X375X387

601X398X388

627X400X433

Control box(L*W*H)

mm

263X182X95

Net weight

Kg

18

27

30

38

Refrigerant type

R410a

Fan duct size

mm

Φ100

Φ150

Sea water pipe

mm

G1/2”-16

Condensed water pipe

Mm

G1/2”-19

Note:A 90 degree turn of the air supply hose will reduce the air volume by more than 25%. When installing, the air pipe should be shortened as much as possible, and the right-angle turn of the air pipe or air duct should be reduced


Model

MS24-E2C

MS32-E2C

MS36-E2C

MS30-S1C

MS36-S1C

Power supply

Ph-V-Hz

1Ph/220V/50Hz

3Ph/380V/50Hz

Cooling

Capacity

BTU

24,000

32,000

36,000

30,000

36,000

Input power

W

1,720

2,400

2,760

2,420

2,620

Rated current

A

7.8

11

12.6

4.9

5.2

EER

4.1

3.9

3.8

3.6

4.0

Heating

Capacity

BTU

27,500

38,400

43,900

36,300

44,300

Input power

W

1,920

2,830

3,300

2,720

3,120

Rated current

A

8.7

12.8

15

5.2

5.8

COP

4.2

4.0

3.9

3.9

4.2

Max.current

A

11.7

18

20.2

5.9

6.3

Sea water flow

M3/h

1.7

2.3

2.5

2.1

2.5

Indoor air flow

M3/h

1,150

1,800

1,800

1,850

1,850

Dehumidification capacity

L/h

3.1

4.5

4.9

4.2

4.9

Noise level

dB(A)

≤59

≤64

≤67

≤65

≤67

Dimension(L*W*H)

mm

707X433X488

756X481X560

762X511X560

755X480X560

760X510X550

Control box(L*W*H)

mm

410X195X115

400X195X105

Net weight

Kg

56

66

88

65

87

Refrigerant type

R410a

R22

Fan duct size

mm

Φ150

Φ200

Sea water pipe

mm

G3/4”-19

G1”-25

Condensed water pipe

Mm

G3/4”-25

Note:A 90 degree turn of the air supply hose will reduce the air volume by more than 25%. When installing, the air pipe should be shortened as much as possible, and the right-angle turn of the air pipe or air duct should be reduced


Send Inquiry