Yacht Air Conditioning/Self-Contained Unit
Features
This self-contained unit, has standard stainless steel, using rivet stainless steel metal structure, and nickel-copper coaxis tube as heat exchanger for sea water side. The fan duct can be roted as required when you install it.The fan blower has advantage such as high static pressure, big air flow and low noise. This self-contained unit has the maximum compact design and better performance. As customer required, we can also provide D-smart control PCB with soft-start function to minimize the starting current.
Model
MS6-E2C
MS9-E2C
MS12-E2C
MS16-E2C
Power supply
Ph-V-Hz
1Ph/220V/50Hz
Cooling
Capacity
BTU
6,000
9,000
12,000
16,000
Input power
W
430
720
980
1,210
Rated current
A
2.0
3.3
4.5
5.5
EER
4.1
3.7
3.6
3.9
Heating
Capacity
BTU
6,500
10,000
13,300
17,700
Input power
W
450
770
1,000
1,270
Rated current
A
2.1
3.5
4.6
5.8
COP
4.2
3.8
3.7
4.0
Max.current
A
3.0
5.3
6.8
8.2
Sea water flow
M3/h
0.42
0.64
0.85
1.15
Indoor air flow
M3/h
250
630
630
810
Dehumidification capacity
L/h
0.7
1.1
1.8
2.1
Noise level
dB(A)
≤45
≤50
≤50
≤54
Dimension(L*W*H)
mm
461X265X283
602X375X387
601X398X388
627X400X433
Control box(L*W*H)
mm
263X182X95
Net weight
Kg
18
27
30
38
Refrigerant type
R410a
Fan duct size
mm
Φ100
Φ150
Sea water pipe
mm
G1/2”-16
Condensed water pipe
Mm
G1/2”-19
Note:A 90 degree turn of the air supply hose will reduce the air volume by more than 25%. When installing, the air pipe should be shortened as much as possible, and the right-angle turn of the air pipe or air duct should be reduced
Model
MS24-E2C
MS32-E2C
MS36-E2C
MS30-S1C
MS36-S1C
Power supply
Ph-V-Hz
1Ph/220V/50Hz
3Ph/380V/50Hz
Cooling
Capacity
BTU
24,000
32,000
36,000
30,000
36,000
Input power
W
1,720
2,400
2,760
2,420
2,620
Rated current
A
7.8
11
12.6
4.9
5.2
EER
4.1
3.9
3.8
3.6
4.0
Heating
Capacity
BTU
27,500
38,400
43,900
36,300
44,300
Input power
W
1,920
2,830
3,300
2,720
3,120
Rated current
A
8.7
12.8
15
5.2
5.8
COP
4.2
4.0
3.9
3.9
4.2
Max.current
A
11.7
18
20.2
5.9
6.3
Sea water flow
M3/h
1.7
2.3
2.5
2.1
2.5
Indoor air flow
M3/h
1,150
1,800
1,800
1,850
1,850
Dehumidification capacity
L/h
3.1
4.5
4.9
4.2
4.9
Noise level
dB(A)
≤59
≤64
≤67
≤65
≤67
Dimension(L*W*H)
mm
707X433X488
756X481X560
762X511X560
755X480X560
760X510X550
Control box(L*W*H)
mm
410X195X115
400X195X105
Net weight
Kg
56
66
88
65
87
Refrigerant type
R410a
R22
Fan duct size
mm
Φ150
Φ200
Sea water pipe
mm
G3/4”-19
G1”-25
Condensed water pipe
Mm
G3/4”-25
Note:A 90 degree turn of the air supply hose will reduce the air volume by more than 25%. When installing, the air pipe should be shortened as much as possible, and the right-angle turn of the air pipe or air duct should be reduced