InRow Cooling for Server Rooms & Data Centers


Core advantages

●Key components are selected from well-known brand.

●Full EC inverter design, automatic adjustment of cooling capacity and air volume output.

●Wet film humidifier, saving 99% of humidification energy.

● L shape or U shape evaporator, large area, small resistance

●Compact outdoor unit, U shaped design, air return on three sides

●High return air temperature design, significantly improved energy efficiency

●Full frontal maintenance, pull-out design.

●Group control, flexible configuration.



Technical Data


CRA Row-Based Air-cooled Aircon

Indoor unit model

CRA3012

CRA3025

CRA3040

CRA3050

CRA3060

Power supply

380V 3Ph~50hz

Air supply

Front air supply

Performance parameter

Cooling capacity(kW)

12.5

25

40

50

60

Sensible capacity(kW)

12.5

25

40

50

60

Max. operation current(A)

27.5

37

50.2

54

57.2

Compressor Qty

1

Fan type

EC centrifuge fan

Fan Qty

3

6

2

3

3

Circulating air volume(m3/h)

3000

5000

8000

10800

12000

Heating capacity(kW)

2

3

6

9

9

Humidification(kg/h)

1

1.5

3

4.5

4.5

Connecting pipe size(30m)

Liquid pipe(mm)

9.52

15.88

15.88

15.88

15.88

Gas pipe(mm)

19.05

22

22

22

22

Humidification inlet pipe(internal thread)

G3/4”

Water pump drain pipe(mm)

ID9.53*OD17.02

Natural drain pipe(mm)

ID16*OD24

Unit dimension and weight

Dimension-W(mm)

300

300

600

600

600

Dimension-D(mm)

1100/1200

Dimension-H(mm)

2000/2200

Weight(kg)

190

210

250

310

310

Outdoor unit performance parameter(40℃)

Flat-plate outdoor unit model

CST013SP

CMT038SP

CMT055SP

CMT077SP

CMT088SP

Centralized outdoor unit model

N/A

CMT038SF

CMT055SF

CMT077SF

CMT088SF

Outdoor unit performance parameter(45℃)

Flat-plate outdoor unit model

N/A

CMT044SP

CMT066SP

CMT088SP

CMT099SP

Centralized outdoor unit model

N/A

CMT044SF

CMT066SF

CMT088SF

CMT099SF

Electronic element specification

Air switch recommended(A)

40

40

63

63

63

Indoor power cable diameter(mm2)

4*6.0+1*6.0

4*6.0+1*6.0

4*16+1*16

4*16+1*16

4*16+1*16

Remark:

  1. Standard working conditions: indoor return air temperature 37℃,RH 24%,outdoor ambient temperature 35℃, ESP=10Pa;
  2. Only cooling+ electric heating or constant temperature and humidity type can be selected. The maximum working current and the recommended air switch are configured according to the constant temperature and humidity unit.
  3. If you need to use centralized outdoor unit, please contact us.
  4. The table above is only part of the parameters, and the specific configuration is subject to the nameplate. For more information about parameters, please contact us.